Maxsys and MX Series Software Administrator’s Guide 65
Chapter 5: Data Setup
This chapter provides information on creating and modifying Data
Setups.
Creating a New Data Setup
Data Setups tell the system how to interpret the input data. Specifically, the Data
Setup provides the order of the input data fields and the code or position that
identifies the beginning and end of each data field. The system uses this
information to parse the Data Setup into the format used for production.
There can be only one Data Setup open at a time. Make sure to save the new
setup before opening another.
The Keyboard Entry utility allows job creation without an input data file.
Sample data can be entered manually using the keyboard or by file reference
in order to create a job. Manually created jobs may be reviewed prior to
production. For more information, refer to
page 211.
Perform the following steps to create a new Data Setup:
1. In
the Data Setup window (Applications | Setups | Data Setup), click the
New icon on the toolbar.
2. Comple
te the fields under the General tab to define the input file. (For
detailed information, refer to “Defining Data Input Files” on page 66.)
The elements on the General tab define for the syst
em what the input data
stream consists of and how it behaves. This determines how the system will
interpret the input data stream it receives.
3. Compl
ete the fields under the Data Fields tab to add data fields. (For detailed
information, refer to “Adding Fields” on page 67.)
The Data Fields tab defines the format of the individ
ual data fields. This
information determines how the system will process individual fields within
the input data stream.
When adding fields, remember that by default the fields in the Data Setup
are set up in the same order of occurrence as in the actual input file, unless
you clear the Fields in Order check box under the Data Fields tab.